Patch Panels
T1, 100 Ohms, 16 Port

VCL Products > Patch Pannels > T1, 100 Ohms, 16 Port High Impedance (Hi-Z) Monitoring Patch Panel

T1, 100 Ohms, 16 Port High Impedance (Hi-Z) Monitoring Patch Panel (T1, 100 Ohms - Version)

Get Data Sheet

The T1 100 Ohms, 16 Port High Impedance Monitoring Patch Panel. The T1 16 Port Monitoring Patch Panel is primarily designed for applications where T1 circuits are required to be “tapped” for non-intrusive monitoring applications. The T1 Monitoring Patch Panel is simultaneously provides up to 16 high-impedance(Hi-Z) outputs on it's monitoring (MON) port(s) from which, both the transmit (Tx) and the receive (Rx) signals of the patched T1 link can be “tapped non-intrusively” (i.e without disturbing or loading the active T1 link(s) in any manner, and connected to T1 Groomers, Probes or Analysers




Product Part Number: VCL-1230-MON-075-BNCF-16

Product Description: 16xE1/T1, 120/100 Ohms RJ45 (F) High Impedance (Hi-Z) Monitoring Patch Panel 19" Shelf 2U High Mount Version with Hardware Set [RJ45 cables not included]

Features

  • Cost effective solution.
  • 19 inch rack mount.
  • High quality and cost effective.
  • Small and compact.

Mechanical Specification

  • Rack Mounting, Standard 19 inch DIN Rack
  • H x D x W : 90mm x 45mm x 485mm
  • Weight : 1.4 kg.

Typical Application Diagram


75 Ohms Monitoring Patchpanel

16 x T1 Monitoring Patch Panel - Circuit Schematic


Shelf image: E1 G.703 - 120 Ohms (RJ45) to 75 Ohms (BNC) Converter Balun Panel

The Hi-Z (432 Ohm) resistive output is provided on the Monitoring (MON) Port of the Patch Panel for connecting to the Groomer / Probe / Analyser.

DIP Switch settings


75 Ohms Monitoring Patchpanel

All four DIP switches must be set to OFF position for non-intrusive monitoring applications.


Connecting T1 Main Link

Shelf image: E1 G.703 - 120 Ohms (RJ45) to 75 Ohms (BNC) Converter Balun Panel

The RJ-45 Connectors Row A and Row B are used for Data IN/Data OUT from/to the Site A and Site B T1 link.


Connecting Hi-Z Output

Shelf image: E1 G.703 - 120 Ohms (RJ45) to 75 Ohms (BNC) Converter Balun Panel

The RJ-45 Connectors Row MON are used for Hi-Z Data OUT from the T1 link connected on Row A and Row B to T1 Groomers, Probes or Analysers.



Valiant Communications is an ISO 9001:2015, ISO 10001:2018, ISO 14001:2015, ISO 27001:2013 and ISO 45001:2018 certified equipment manufacturer.